ABB · ACS880
Warning generated by on-time timer 2, indicating that a predefined operational time limit has been reached or exceeded. This often serves as a maintenance reminder or an alert for extended operation. Failure to address could lead to component wear or overdue service.
Click steps to track your progress.
Identify the specific equipment or process that On-time Timer 2 is configured to monitor by reviewing system documentation.
Note the current accumulated time value displayed in parameter P4-04.00 (Current On-time 2).
Perform the required preventative maintenance (e.g., gearbox oil change, motor fan inspection) corresponding to the timer's purpose.
Reset On-time Timer 2 to zero by setting parameter P4-04.02 (Reset Timer 2) to '1' (Execute) after the maintenance is completed.
Update the limit in parameter P4-04.01 (On-time 2 Limit) if the operational interval needs to be extended or reduced.