Beckhoff · TwinSAFE Logic FB
This fault indicates a discrepancy in E-Stop input group 2, similar to 'FB ESTOP Bit 1', but specifically when the 'Safe Inputs after Disc Error' option is activated. This means that even after a discrepancy, the FB attempts to maintain a safe state for the inputs, but a persistent or critical discrepancy has occurred, preventing normal operation and requiring intervention.
Click steps to track your progress.
Verify the continuity of both E-Stop input lines for Group 2 from the E-Stop button to the safety controller's input terminals (e.g., X8.1, X8.2).
Observe the diagnostic status of both Group 2 input channels via the safety controller's software during both idle and active states.
Measure the voltage at the safety controller's E-Stop Group 2 input terminals (e.g., X8.1, X8.2) while the system is attempting to be active.
Inspect the E-Stop button for Group 2 for mechanical wear, debris, or damage that could impede consistent contact closure.
Check and adjust the discrepancy time parameter (e.g., P_ESTOP_ACTIVE_DISC_TIME_G2) in the safety controller if asynchronous switching is occurring.