A discrepancy error in 'MuteIn1'/'MuteIn2' was detected and has not yet been acknowledged or reset. This indicates a persistent underlying issue with muting input group 1 that needs active resolution and acknowledgment before normal operation can resume. The system will remain in a safe, stopped state.
Click steps to track your progress.
1. Re-evaluate and resolve the underlying causes for 'Muting Discrepancy Error - Muting Group 1' (ref=36) by checking sensor alignment, cleanliness, and wiring.
2. Activate the safety system reset input (e.g., pressing the HMI 'Reset' button or a physical input X1.5) and verify its signal at the safety PLC terminal.
3. Monitor the raw input states of 'MuteIn1' and 'MuteIn2' in the safety controller's diagnostic view to confirm they are stable and consistent before attempting a reset.
4. Check the safety controller's diagnostic logs for any other active faults that might be preventing the reset of this specific muting error.
5. Power cycle the safety controller after ensuring all physical faults are cleared, then attempt the reset procedure again.