GROUP Value 1

Function Block Error (Group)

Beckhoff · TwinSAFE Logic FB

What does GROUP Value 1 mean?

At least one TwinSAFE function block (FB) within the EL/EJ69x0 group has entered an ERROR state. This indicates a localized issue within a specific safety function, which then propagates to the group level, causing the entire group to halt safe operation. Investigation of individual FB diagnostics is required.

Common Causes

  • A specific TwinSAFE function block (e.g., FB_EmergencyStop, FB_DoorMonitoring) within the group has entered an ERROR state.
  • Incorrect parameterization of one or more individual function blocks (e.g., P6-05 for delay time) leading to an internal error condition.
  • Faulty safety input device (e.g., EL1957 module with shorted input) connected to a specific function block, preventing it from clearing its error.
  • Logic programming error within a specific function block preventing it from reaching a safe operating state.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    1. Open the TwinCAT System Manager and navigate to the safety project to identify which specific TwinSAFE function block is in error.

  2. 2

    2. Examine the detailed diagnostic flags and error codes for the identified problematic function block.

  3. 3

    3. Verify the operational status and input signals of the safety devices connected to the faulty function block (e.g., OSSD signals at EL1957 terminals).

  4. 4

    4. Check the parameter settings (e.g., P6-05) of the individual function block against the application requirements.

  5. 5

    5. Attempt to acknowledge and reset the individual function block error via the TwinCAT System Manager.