xxxx 0100

Invalid CRC

Beckhoff · TwinSAFE Logic FB

What does xxxx 0100 mean?

A Cyclic Redundancy Check (CRC) error was detected in an FSoE telegram. This indicates data corruption during transmission, usually due to noise, damaged cabling, or faulty network components. It compromises safety integrity and prevents reliable communication, forcing a safe state.

Common Causes

  • Cyclic Redundancy Check (CRC) error detected.
  • Data corruption during transmission.
  • Faulty communication cable or connector.
  • Electromagnetic interference corrupting data.
  • Incorrect CRC calculation on sender or receiver side.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect all Ethernet cabling and connectors between FSoE devices for damage, proper shielding, and secure connections.

  2. 2

    Check for strong electromagnetic interference (EMI) sources near the communication cables.

  3. 3

    Verify network switches or couplers in the FSoE path are suitable for industrial Ethernet and functioning correctly.

  4. 4

    Perform a cable test to measure signal integrity and identify faulty segments.

Browse all codes in this manual (60)