Bosch Rexroth · IndraDrive MPx02
This non-fatal error indicates that the IndraDrive MPx02 device itself has detected an overtemperature condition and initiated a shutdown to prevent damage. This is a protective measure when internal components, such as power semiconductors or control electronics, exceed their safe operating temperature.
Click steps to track your progress.
Check the cooling fan(s) on the IndraDrive MPx02 for proper operation. Clean any dust or debris blocking heatsink fins or air vents.
Verify that the ambient temperature in the control cabinet or mounting location is within the drive's specified operating range.
Reduce the load on the drive if it is consistently operating at or above its rated capacity. Check motor and application sizing.
Inspect the drive for proper mounting and sufficient clearance around its heatsink for adequate airflow.
Allow the drive to cool down. If the fault reoccurs immediately after cooling, an internal temperature sensor may be faulty, requiring service.