F2818

Phase failure

Bosch Rexroth · IndraDrive MPx02

What does F2818 mean?

One or more phases of the three-phase AC mains input power supply have failed or are missing. This leads to an unbalanced or insufficient supply voltage for the drive's rectifier and DC bus. Operating with a phase failure can cause excessive ripple on the DC bus, overheating, and damage to the drive components.

Common Causes

  • Blown fuse on one of the input phases
  • Open circuit breaker for an input phase
  • Loose or broken wiring in the mains input circuit
  • Mains contactor failure for one phase
  • Power grid issue causing loss of a phase

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Measure the three-phase AC supply voltage (L1-L2, L2-L3, L3-L1) at the drive's input terminals to confirm balanced and nominal values.

  2. 2

    Inspect the main power cabling and connections from the upstream power source to the drive's input terminals for damage, looseness, or disconnections.

  3. 3

    Check all upstream protective devices (circuit breakers, fuses, main contactors) for proper operation, tripped status, or signs of failure, ensuring all phases are correctly supplied.

  4. 4

    Verify the drive's input power parameters (e.g., nominal voltage, phase monitoring thresholds) match the actual mains supply and application requirements.

Browse all codes in this manual (99)
Verified technical data. Last updated: April 2026

Related Faults

F2003Motion step skippedF2004Error in motion profileF2005Cam shaft invalid
Source: Bosch Rexroth IndraDrive MPx02
Open Manual (Page 145)Search more codes in this manual