Bosch Rexroth · IndraDrive MPx02
This non-fatal safety technology error indicates that a safety-related reference or datum is missing when attempting to select a safety-related end position. This prevents the drive from reliably establishing its safe operating limits, impacting safety functions like Safe Limited Position (SLP).
Click steps to track your progress.
Verify that the safety reference point for the axis has been correctly established and stored according to the machine's commissioning procedure.
Check the primary and secondary encoder feedback signals for integrity and proper operation.
Review safety parameters in the IndraDrive MPx02, specifically those defining reference positions and safety limits, to ensure correct configuration.
Inspect the wiring and connections of the safety encoder for damage, loose terminals, or improper shielding.
If an external safety PLC is used, verify its programming and communication with the IndraDrive MPx02 regarding reference position management.