Bosch Rexroth · IndraDrive MPx02
This non-fatal safety technology error signifies that a critical safety-related reference is missing. This reference is essential for the IndraDrive MPx02 to perform safety functions correctly, potentially impacting safe motion or standstill monitoring.
Click steps to track your progress.
Re-establish the safety reference point for the axis using the commissioning tools, ensuring it is properly saved.
Verify the functionality and wiring of the safety encoder or absolute position feedback system.
Check safety configuration parameters in the IndraDrive MPx02 for consistency and completeness, especially those related to position references.
Perform a safety function test to confirm proper operation of all safety-related position monitoring.
If the issue persists, consider reloading the last known good safety parameter set or re-commissioning the safety functions.