Bosch Rexroth · IndraDrive MPx02
This non-fatal safety error indicates that the command received by the IndraDrive MPx02 to clear safety-related errors is incorrect or invalid. This prevents the system from being reset after a safety fault, maintaining the safety shutdown state.
Click steps to track your progress.
Verify the exact sequence, timing, and value of the safety error clear command being sent by the master controller or safety PLC.
Check safety parameters in the IndraDrive MPx02 related to error acknowledgment and clearing logic.
Ensure that all necessary preconditions for clearing safety errors (e.g., no active safety violation, E-stop reset) are met.
Inspect the communication link between the master controller and the IndraDrive MPx02 for errors.
Refer to the IndraDrive MPx02 safety manual for the precise error clearing procedure and required command structure.