F3146

System error channel 2

Bosch Rexroth · IndraDrive MPx02

What does F3146 mean?

This non-fatal safety error indicates a system-level fault detected within channel 2 of the safety functions on the IndraDrive MPx02. Safety systems often employ dual-channel architecture for redundancy, and an error in one channel means its independent operation or monitoring has failed.

Common Causes

  • Internal hardware fault within channel 2 of the IndraDrive MPx02's safety module.
  • Component failure in the signal path of channel 2 for safety inputs or outputs.
  • Firmware or software issue affecting the processing logic of channel 2.
  • Electromagnetic interference specifically affecting channel 2 components.
  • Damage to the internal PCB or safety-related components specific to channel 2.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Perform a full power cycle of the IndraDrive MPx02 to attempt to clear transient internal faults.

  2. 2

    Check for any external wiring issues or component failures that are specifically connected to safety functions monitored by channel 2.

  3. 3

    Verify the firmware version of the IndraDrive MPx02 and update to the latest compatible version if necessary.

  4. 4

    Ensure proper grounding and shielding to mitigate electromagnetic interference that could affect internal circuits.

  5. 5

    If the error persists after thorough external checks, this typically indicates an internal hardware defect within the IndraDrive MPx02's safety module, requiring replacement or professional repair.

Browse all codes in this manual (99)
Verified technical data. Last updated: April 2026

Related Faults

F2003Motion step skippedF2004Error in motion profileF2005Cam shaft invalid
Source: Bosch Rexroth IndraDrive MPx02
Open Manual (Page 5)Search more codes in this manual