Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

F3151

Safety command for system halt incorrect

Bosch Rexroth · IndraDrive MPx02

What does F3151 mean?

This non-fatal safety error indicates that the command received by the IndraDrive MPx02 to initiate a safety-related system halt is incorrect or invalid. This implies a failure in the safe shutdown process, which is critical for machine safety.

Common Causes

  • Incorrect sequence or timing of the safety halt command from the master controller or safety PLC.
  • Mismatch between the expected and received safety halt command (e.g., wrong bit pattern or value).
  • Communication error preventing the correct safety halt command from reaching the IndraDrive MPx02.
  • Incorrect parameterization of the safety halt logic.
  • Failure of internal safety logic to correctly process the halt command.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the exact sequence, timing, and value of the safety system halt command being sent by the master controller or safety PLC.

  2. 2

    Check safety parameters in the IndraDrive MPx02 related to safety halt logic and response.

  3. 3

    Inspect the communication link between the master controller and the IndraDrive MPx02 for errors.

  4. 4

    Ensure that any external safety devices triggering the halt command are functioning correctly.

  5. 5

    If the error persists despite correct external commands, a power cycle of the IndraDrive MPx02 may be necessary to clear internal logic states.

Browse all codes in this manual (99)
Verified technical data. Last updated: April 2026

Related Faults

F2003Motion step skippedF2004Error in motion profileF2005Cam shaft invalid
Source: Bosch Rexroth IndraDrive MPx02
Open Manual (Page 5)Search more codes in this manual