Bosch Rexroth · IndraDrive MPx02
This safety technology error indicates that the actual position increment of the motor, as monitored by the safety function, has exceeded a defined safety-related limited increment threshold on the IndraDrive MPx02. This typically means the motor moved further than permitted in a safe monitored mode, triggering a safety stop.
Click steps to track your progress.
Review and adjust the safety-related limited increment parameter (e.g., S-0-0196 'Limited increment position range') in the IndraDrive MPx02, ensuring it is appropriate for the application.
Check the tuning of the speed and position control loops for stability and accuracy.
Verify the motor encoder for correct and clean position feedback. Inspect wiring for noise or loose connections.
Analyze the machine's motion profile and ensure that commanded position changes do not exceed the set safety increment.
Inspect the mechanical system for any binding, excessive backlash, or external forces that could cause unintended movement.