Bosch Rexroth · IndraDrive MPx02
This safety technology error indicates that the actual velocity of the motor has exceeded a safety-related velocity threshold configured in the IndraDrive MPx02. This is a critical safety violation, implying the motor is moving too fast for the current safety-monitored state, leading to an immediate safety stop.
Click steps to track your progress.
Review and adjust the safety-related velocity threshold parameters (e.g., S-0-0100) in the IndraDrive MPx02, ensuring they are appropriate for the application's safety requirements.
Check the tuning of the velocity control loop to ensure stable and accurate speed regulation.
Verify the motor encoder for accurate and consistent velocity feedback. Inspect wiring for damage or noise.
Analyze the commanded motion profile and machine operation to ensure that the motor's speed never exceeds the set safe velocity threshold.
Inspect the mechanical system for any binding, excessive play, or external forces that could cause unintended acceleration.