Bosch Rexroth · IndraDrive MPx02
This safety technology error indicates that the actual acceleration of the motor has exceeded a safety-related acceleration threshold configured in the IndraDrive MPx02. This is a critical safety violation, implying an uncontrolled or excessively rapid change in speed, leading to an immediate safety stop.
Click steps to track your progress.
Review and adjust the safety-related acceleration threshold parameters (e.g., S-0-0092) in the IndraDrive MPx02, ensuring they are appropriate for the application's safety requirements.
Check the tuning of the current and velocity control loops, specifically feed-forward and gain settings, to prevent overshoot.
Inspect the mechanical system for any sudden load changes, binding, or play that could induce high acceleration spikes.
Verify the motor encoder for accurate feedback, as noisy position data can lead to erroneous acceleration calculations.
Analyze the commanded motion profile to ensure that programmed acceleration ramps do not exceed the safety threshold.