F7030

Pos. window for safety rel. operational stop exceeded

Bosch Rexroth · IndraDrive MPx02

What does F7030 mean?

This safety technology error indicates that the motor's actual position has moved outside the defined position window for a safety-related operational stop on the IndraDrive MPx02. This means the axis is not maintained within its safe 'standstill' range, triggering a safety shutdown.

Common Causes

  • Incorrectly parameterized safety-related position window for operational stop (e.g., S-0-0105 'Safe operational stop window').
  • Insufficient holding torque from the motor or an ineffective holding brake.
  • External mechanical forces acting on the axis, causing it to drift.
  • Encoder noise or drift leading to false out-of-window detection.
  • Motor or drive parameter tuning issue, leading to poor standstill regulation.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Review and adjust the safety-related position window parameter (e.g., S-0-0105) for operational stop in the IndraDrive MPx02, ensuring it is appropriate for the application's permissible drift.

  2. 2

    Verify the motor's holding torque and the functionality of any mechanical holding brake. Ensure sufficient torque to hold the load.

  3. 3

    Inspect the mechanical system for any external forces, vibrations, or imbalances that could cause the axis to move while in operational stop.

  4. 4

    Check the motor encoder for noise or intermittent signals that could cause erroneous position readings.

  5. 5

    Adjust the standstill controller parameters in the IndraDrive MPx02 to improve position holding accuracy.

Browse all codes in this manual (99)
Verified technical data. Last updated: April 2026