Bosch Rexroth · IndraDrive MPx02
This safety technology error indicates that the IndraDrive MPx02 has detected motion in an incorrect or unintended direction, violating a safety-related directional monitoring function. This could be due to a control error or external influence, leading to an immediate safety stop.
Click steps to track your progress.
Review and adjust the safety-related direction monitoring parameter (e.g., S-0-0102) in the IndraDrive MPx02 to ensure it aligns with the intended safe directions of motion.
Verify the motion program in the master controller or PLC, ensuring correct direction commands are issued.
Check the motor phasing and encoder wiring for correct connections. If necessary, reverse motor phases (U, V, W) or encoder direction parameter (S-0-0130 'Encoder direction of rotation').
Inspect the mechanical system for excessive backlash, loose couplings, or other defects that could cause unintended reversal.
Verify the motor encoder for correct direction sensing, checking for potential noise or signal issues.