Bosch Rexroth · IndraDrive MPx02
This fatal safety error indicates that a safety technology configuration parameter in the IndraDrive MPx02 is invalid or inconsistent. This means the drive's safety logic cannot be reliably established, rendering the safety functions inoperable and causing a system shutdown.
Click steps to track your progress.
Review all safety technology configuration parameters in the IndraDrive MPx02, comparing them against the machine's safety documentation and drive manual.
Attempt to load a previously saved, validated safety parameter set that is known to be correct for the application.
Verify that the firmware version of the IndraDrive MPx02 is compatible with the version of the safety parameters.
If an external safety PLC is used, ensure its safety program and parameters match the drive's configuration.
Perform a safety system re-commissioning, if necessary, meticulously verifying each parameter setting.