Danfoss · VLT AutomationDrive FC 301/302
A parameter has been configured with a value that falls outside its acceptable minimum or maximum range within a specific internal code range. This prevents the drive from operating correctly and can lead to unexpected behavior.
Click steps to track your progress.
Identify the specific parameter code displayed on the LCP associated with this fault.
Refer to the drive's operating manual to find the valid range (minimum/maximum) for the identified parameter.
Adjust the parameter value (e.g., P1-54 Motor rated current) to be within its acceptable limits.
If parameters were loaded from a file, verify the file matches the exact drive model and power rating.
Perform a factory reset via Parameter P14-22 (Reset options) set to 2 (Load LCP defaults) and re-enter critical parameters.