EL
ErrorLib
Brands
||
  1. Home
  2. Danfoss
  3. VLT AutomationDrive FC 301/302
  4. 5123
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

5123

Option in slot A: Hardware incompatible with control board

Danfoss · VLT AutomationDrive FC 301/302

What does 5123 mean?

The hardware of the option card installed in slot A is incompatible with the control board hardware. This prevents proper integration and function of the option, requiring a compatible replacement.

Common Causes

  • Option card (e.g., fieldbus, I/O extension) is physically installed in slot A but has a different hardware revision or model that is not supported by the main control board.
  • Control board firmware is too old to recognize the newer option card, or the option card firmware is too old for the control board.
  • Incorrect drive model or series for which the option card was designed.
  • Physical damage to the option card or slot A connector preventing proper identification or communication.
  • Incorrect dip switch or jumper settings on the option card, causing it to report an incompatible configuration.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Identify the exact part number and revision of the option card installed in slot A.

  2. 2

    Consult the drive's compatibility matrix to verify the option card's compatibility with the control board's hardware and firmware versions.

  3. 3

    Replace the option card in slot A with a compatible model and revision.

  4. 4

    Ensure the option card is securely seated in slot A and inspect for any bent pins on the connector.

  5. 5

    Update the drive firmware to the latest version, as it may include expanded option card support.

Browse all codes in this manual (66)
Verified technical data. Last updated: April 2026

Related Faults

#14Earth (ground) fault#32Motor phase W missing#36Mains failure
Source: Danfoss VLT AutomationDrive FC 301/302
View Official PDFSearch more codes in this manual