SP0003

DC Link Fuse Blown

Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters

What does SP0003 mean?

The DC link fuse on the spindle amplifier is blown, indicating an overcurrent event or a short circuit in the DC bus. This results in complete loss of power to the motor.

Common Causes

  • Short circuit in the spindle motor windings or power cables.
  • Faulty spindle amplifier output stage (e.g., IGBT failure).
  • Overvoltage on the DC link causing excessive current draw.
  • Ground fault within the spindle motor or cabling.
  • Incorrect fuse rating or counterfeit fuse installed.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Measure the resistance between each motor phase (U, V, W) and ground.

  2. 2

    Visually inspect the motor power cables for insulation damage.

  3. 3

    Measure the DC link voltage (terminals P+, P-) under load.

  4. 4

    Check the integrity of the spindle amplifier's internal DC bus capacitors.

  5. 5

    Verify the rating of the installed DC link fuse matches the amplifier specification.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026