Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
The DC link fuse on the spindle amplifier is blown, indicating an overcurrent event or a short circuit in the DC bus. This results in complete loss of power to the motor.
Click steps to track your progress.
Measure the resistance between each motor phase (U, V, W) and ground.
Visually inspect the motor power cables for insulation damage.
Measure the DC link voltage (terminals P+, P-) under load.
Check the integrity of the spindle amplifier's internal DC bus capacitors.
Verify the rating of the installed DC link fuse matches the amplifier specification.