DS0016

Scale Distance Out of Range

Fanuc · Series 0i-MODEL F Plus Parameter

What does DS0016 mean?

This alarm is issued if parameter Nos. 1883 and 1884, which define the distance from the scale zero point (for a linear scale with absolute address reference marks) or the base point (for a linear scale with an absolute address zero point) to the reference position, are set to a value beyond the allowed range. The permitted range for this distance is -999,999,999,999 to +999,999,999,999.

Common Causes

  • The calculated distance or travel for a scale is outside its defined operating range.
  • Encoder signal indicates movement beyond physical limits.
  • Incorrect scale factor or resolution set.
  • Mechanical obstruction preventing full range of motion.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the values of parameter No. 1883 and parameter No. 1884 for the affected axis.

  2. 2

    Ensure the combined distance defined by parameters 1883 and 1884 is within the valid range of -999,999,999,999 to +999,999,999,999.

Browse all codes in this manual (13)
Verified technical data. Last updated: March 2026

Related Faults

Source: FANUC Series 0i-MODEL F Plus Parameter
Fanuc DS0016 (Scale Distance Out of Range) — Technical Refe… | ErrorLib