Fanuc · R-30iB Mate + Mate Plus Robot
This alarm (G:i A:j) indicates that an excessive disturbance was assumed in the servo software at the start of operation, detecting an abnormal load. Possible causes include a robot collision, increased mechanical load on the axis, or issues like welding interference. This poses a risk of mechanical damage or operational halt.
Click steps to track your progress.
Check whether the robot has collided or if the machinery load of the corresponding axis is increased.
Verify whether the load settings are valid and correctly configured in the system.
Check whether the brake of the corresponding axis is fully released.
Check whether the load weight is within the rated range for the robot; if the weight exceeds the upper limit, decrease it.
Verify whether the voltage input to the controller is within the rated voltage specifications.
Replace the servo amplifier for the affected axis.