SRVO-084

Line Tracking Pulsecoder Backup Battery Not Connected

Fanuc · R-30iB Mate + Mate Plus Robot

What does SRVO-084 mean?

This alarm occurs if the backup battery for the absolute position of the line tracking Pulsecoder has not been connected. This can lead to loss of absolute position data upon power cycle.

Common Causes

  • The backup battery for the Line Tracking Pulsecoder is not connected or is depleted.
  • Absence of power to the pulsecoder's internal battery circuit.
  • Faulty battery connection terminal on the pulsecoder.
  • Incorrect pulsecoder model installed which does not require a backup battery.
  • Internal failure of the pulsecoder's battery management system.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the backup battery is correctly connected to the Line Tracking Pulsecoder.

  2. 2

    Measure battery voltage at its terminals to confirm it is within specification.

  3. 3

    Inspect the battery connection terminals for corrosion or damage.

  4. 4

    Confirm the pulsecoder model is compatible with the drive's line tracking feature.

  5. 5

    Replace the backup battery if its voltage is low or depleted.

Browse all codes in this manual (53)
Verified technical data. Last updated: April 2026