EL
ErrorLib
Brands
||
  1. Home
  2. Fanuc
  3. Series 0i-D/0i Mate-D Maintenance
  4. DS0009
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

DS0009

ILLEGAL EXECUTION SEQUENCE

Fanuc · Series 0i-D/0i Mate-D Maintenance

What does DS0009 mean?

This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the control detected an illegal execution sequence. This implies a logic error in the program or an unexpected state transition.

Common Causes

  • Logic error in the NC program or PMC ladder logic leading to an invalid command sequence.
  • Incorrect macro program execution or unexpected M-code/T-code call.
  • Corrupted NC program data or PMC program causing irregular flow.
  • Unexpected machine state transition during program execution.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Review the NC program and PMC ladder logic for any sequences that could lead to an invalid or unexpected command execution.

  2. 2

    Check for any conditional logic (e.g., IF statements, GOTO commands) that might lead to an unintended program flow.

  3. 3

    Verify the machine's current operational mode and state transitions (e.g., manual to auto, program restart) for any irregularities.

  4. 4

    Examine any recently modified programs or macros for logical errors or unsupported commands.

  5. 5

    Perform a step-by-step execution of the program in single-block mode to pinpoint the exact point of the illegal sequence.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

361ABNORMAL PHASE DATA(INT)364SOFT PHASE ALARM(INT)365BROKEN LED(INT)
Source: Fanuc Series 0i-D/0i Mate-D Maintenance
Open Manual (Page 487)Search more codes in this manual