Fanuc · Series 0i-D/0i Mate-D Maintenance
This Fanuc Series 0i-D/0i Mate-D PMC alarm indicates that an unsupported function is used within the sequence program (ladder program). This means the PMC model or its firmware does not support a specific command or feature in the program.
Click steps to track your progress.
Review the sequence program to identify any advanced or specific functions that might not be compatible with the current PMC model or its firmware version.
Verify the PMC model and firmware version installed on the machine against the requirements of the sequence program.
Attempt to simplify or rewrite the section of the sequence program using the unsupported function with standard PMC logic.
Consult the FANUC PMC programming manual for the specific PMC series to confirm supported functions and their proper syntax.
If simplifying the program is not feasible, contact FANUC support to inquire about PMC firmware updates or compatible PMC modules that support the required function.