Fanuc · Series 0i-D/0i Mate-D Maintenance
This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the stored stroke check 2 on the negative side for an axis has been exceeded. This is a secondary software limit, often used for specific work zones or fixtures.
Click steps to track your progress.
Review the NC program for commands that attempt to move the axis beyond the negative limit defined by stored stroke check 2.
Verify the parameter settings for stored stroke limit check 2 on the negative side for the specific axis.
Check for any physical obstructions or workholding fixtures that might be within the defined stroke check 2 area.
Temporarily jog the axis in the positive direction, then reset the alarm to clear the overtravel condition.
Ensure that machine coordinates are accurate and properly calibrated before resuming operation.