IE0009

ILLEGAL MCN COODINATE

Fanuc · Series 0i-D/0i Mate-D Maintenance

What does IE0009 mean?

This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the control detected a displacement of a machine coordinate at a check point. This implies an inconsistency in the machine's internal position tracking.

Common Causes

  • Loss of the machine's reference position (home position) due to power loss or encoder issue.
  • Incorrect machine coordinate offset or work offset applied.
  • Faulty position feedback device (encoder/scale) or its connection.
  • Unexpected mechanical shift or slippage in the axis drive system.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Re-establish the machine's reference position (zero return) for the affected axis.

  2. 2

    Verify that no unexpected shifts or offsets have been applied to the machine coordinate system (e.g., G50/G92 offsets).

  3. 3

    Check the integrity and mounting of the position feedback device (encoder/scale) for the affected axis.

  4. 4

    Review diagnostic screens for any discrepancies between the commanded position and actual machine position.

  5. 5

    Inspect mechanical components for signs of slippage or excessive backlash that could affect coordinate accuracy.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026