EL
ErrorLib
Brands
||
  1. Home
  2. Fanuc
  3. Series 30i/31i/32i-MODEL B Parameter
  4. DS1448
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

DS1448

Scale Zero Point/Base Point Distance Out of Range

Fanuc · Series 30i/31i/32i-MODEL B Parameter

What does DS1448 mean?

This alarm is issued if the distance from the scale zero point (for a linear scale with absolute address reference marks) or the base point (for a linear scale with an absolute address zero point) to the machine's reference position, as configured by parameters 1883 and 1884, exceeds the allowable range of -999,999,999,999 to +999,999,999,999. This indicates an invalid parameter setting for the reference position.

Common Causes

  • Scale zero point distance exceeds maximum allowable value.
  • Base point distance measurement is out of specification.
  • Calibration error detected in the scale measurement system.
  • Physical limit for scale zero point exceeded.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check parameters 1883 and 1884 — verify the set machine coordinate value, converted to detection units (machine coordinate × CMR), is within the range of -999,999,999,999 to +999,999,999,999.

  2. 2

    Ensure that the physical scale area on the linear scale does not extend across the scale zero point or base point, as this can cause calculation errors.

  3. 3

    Re-establish the reference position by following the procedure in the manual (steps <1> through <4> for parameters 1883 and 1884), paying close attention to the machine coordinate measurement.

Browse all codes in this manual (12)
Verified technical data. Last updated: April 2026

Related Faults

DS0016Scale Zero Point/Base Point Distance Out of RangeDS0300APC ALARM: NEED REF RETURNER54NC-PMC I/F ASSIGNMENT ERROR
Source: FANUC Series 30i/31i/32i-MODEL B Parameter
Open Manual (Page 129)Search more codes in this manual