369

DATA TRANS. ERROR(INT)

Fanuc · Series 30i/31i/32i-MODEL B Plus

What does 369 mean?

This internal alarm signals a communication data error, primarily caused by noise affecting the data transmission. Unstable position data from the Pulsecoder can lead to incorrect axis control or unexpected machine behavior.

Common Causes

  • Noise causing unstable position data from the Pulsecoder.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check CNC diagnosis information No.356 (Built-in detector) and No.357 (Separate detector) for incremented values, which indicate noise effects. The value is cleared when the CNC unit is powered off.

Browse all codes in this manual (38)