386

DATA TRANS. ERROR(EXT)

Fanuc · Series 30i/31i/32i-MODEL B Plus

What does 386 mean?

This external alarm signals a communication data error from the separate detector, primarily caused by noise. Unstable position data from the separate detector can lead to erratic or inaccurate control.

Common Causes

  • Noise causing unstable position data from the separate detector.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check CNC diagnosis information No.356 (Built-in detector) and No.357 (Separate detector) for incremented values, which indicate noise effects. The value is cleared when the CNC unit is powered off.