EL
ErrorLib
Brands
||
  1. Home
  2. Fanuc
  3. Series 30i/31i/32i-MODEL B Plus
  4. A.
About·Privacy·Terms

ErrorLib — Industrial Fault Code Library

Disclaimer: ErrorLib is an independent technical reference tool. While we aim for accuracy, always verify with the manufacturer’s official service manuals before performing maintenance on industrial equipment. ErrorLib is not affiliated with the brands listed.

A.

Inverter: IPM alarm (N axis) or Overheat

Fanuc · Series 30i/31i/32i-MODEL B Plus

What does A. mean?

An Intelligent Power Module (IPM) alarm has occurred for the N axis. This can indicate a short-circuit or ground fault in the power lead phases or motor winding phases, or an internal IPM failure. Additionally, it may signal an IPM overheat condition, often caused by the motor operating under harsh conditions or excessively high ambient temperatures. This fault implies a critical power module issue.

Common Causes

  • Short-circuit between power lead phases or ground fault in them
  • Short-circuit between motor winding phases or ground fault in them
  • The motor is being used under a harsh condition
  • The ambient temperature is high
  • Servo Amplifier failure

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Measure insulation resistance of power lead phases to ground using a megohmmeter.

  2. 2

    Measure insulation resistance between motor winding phases and from each phase to ground.

  3. 3

    Assess the motor's operating conditions and load to ensure they are within specifications.

  4. 4

    Measure the ambient temperature around the inverter and confirm it is within specified environmental limits.

  5. 5

    If external electrical and environmental checks are good, replace the Servo Amplifier.

Browse all codes in this manual (38)
Verified technical data. Last updated: April 2026

Related Faults

1Inverter Internal Cooling Fan Stopped2Inverter Control Power Supply Undervoltage366PULSE MISS(INT)
Source: Fanuc Series 30i/31i/32i-MODEL B Plus
Open Manual (Page 92)Search more codes in this manual