Fanuc · Series 30i/31i/32i-MODEL B Plus
A change in position data reported by the serial sensor was detected as exceeding the anticipated range. If this alarm occurs at machine startup, it can stem from a parameter setting error or cable shielding issues. If it arises during normal machine operation, a cable shielding problem is the more likely cause, suggesting an anomaly in position feedback.
Click steps to track your progress.
Refer to the 'Parameters Related to Start-up' section in the FANUC AC SPINDLE MOTOR αi series Parameter Manual (B-65280EN) and verify all sensor setting parameters.
Check the shielding of the cable between the sensor (serial) and Spindle Amplifier for damage or improper termination.
Consult the 'Detectors' section in the FANUC SERVO AMPLIFIER αi series Descriptions (B-65282EN) for detailed information on cable specifications and installation.