Indramat · CLM01.3-M Flying Cutoff Control
The regenerative load from the connected drives exceeds the capacity of the Indramat HVE or HVR power supply unit. This means too much energy is being fed back into the DC bus during deceleration, potentially causing overvoltage or overheating issues.
Click steps to track your progress.
Reduce the allowable deceleration times for the connected drives in the application parameters to decrease regenerative power.
Evaluate if the Indramat HVE or HVR power supply unit is appropriately sized for the combined regenerative power of all connected drives.
Consider using a drive controller with a smaller peak current capacity if the current setup is oversized for the regenerative load.
Inspect any external braking resistors and their connections, verifying resistance and thermal protection.