Indramat · CLM01.3-M Flying Cutoff Control
This warning from the Indramat DIAX04 SSE-03VRS indicates an error during the index check in the multiplex channel. During cyclical data exchange, the index used to access the S-0-0370 (Configuration list for MDT data container) points to a non-initialized field in the list, preventing proper data access.
Click steps to track your progress.
Verify the programming of the control system that generates the index for accessing the S-0-0370 list, ensuring it points to valid, initialized fields.
Check the configuration and initialization of the S-0-0370, Configuration list for MDT data container parameter in the Indramat DIAX04 SSE-03VRS, ensuring all necessary fields are properly defined.
Re-initialize the drive configuration or relevant parameters to ensure the MDT data container list is correctly set up.
Review the cyclical data exchange timing and synchronization between the controller and drive to rule out timing-related issues.