F207

Switching to uninitialized operation mode

Indramat · DIAX 04

What does F207 mean?

The DIAX04 SSE-03VRS drive attempted to switch to an operation mode that has not been properly initialized or configured. This fault typically occurs during startup or mode transitions when necessary parameters for the target operation mode are missing or invalid, preventing the drive from executing commands safely.

Common Causes

  • Required operation mode parameters for the DIAX04 SSE-03VRS are not set or are invalid (e.g., S-0-0032, S-0-0033).
  • An unsupported or non-existent operation mode was commanded to the drive.
  • Internal memory corruption or parameter storage issue within the DIAX04 SSE-03VRS unit.
  • Firmware incompatibility or corruption related to operation mode management.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify all relevant operation mode parameters (e.g., S-0-0032, S-0-0033) in the DIAX04 SSE-03VRS controller match the desired and supported operation modes.

  2. 2

    Ensure the commanded operation mode is valid and supported by the DIAX04 SSE-03VRS firmware and hardware configuration.

  3. 3

    Reload known good parameters or restore default settings to the DIAX04 SSE-03VRS and reconfigure necessary parameters.

  4. 4

    Check for any firmware updates or known issues related to operation mode switching for the DIAX04 SSE-03VRS.

  5. 5

    If the issue persists, inspect the drive's internal diagnostics for additional clues or consider a hardware fault.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026

Related Faults

F208UL The motor type has changedF209PL Load parameter default valuesF218Amplifier overtemp. shutdown
Source: DIAX 04
Open Manual (Page 5)Search more codes in this manual