F236

Excessive position feedback difference

Indramat · DIAX 04

What does F236 mean?

The DIAX04 SSE-03VRS drive has detected a significant discrepancy between its internal commanded position and the actual position reported by the feedback system. This fault typically occurs in applications with high-precision positioning requirements or when there's a mechanical issue preventing the motor from accurately reaching its target. It prevents inaccurate movements and potential collisions.

Common Causes

  • Mechanical slippage or backlash in the drive train between the motor and the load.
  • Motor encoder is slipping on the motor shaft or its coupling is loose.
  • Faulty motor encoder providing incorrect position feedback to the DIAX04 SSE-03VRS.
  • Insufficient motor torque to move the load to the commanded position, resulting in a large following error.
  • Incorrectly set position loop gain (e.g., S-0-0103) or monitoring window (e.g., S-0-0044) in the DIAX04 SSE-03VRS.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the mechanical system for any backlash, slippage, or excessive friction. Check couplings, gears, and belts for integrity.

  2. 2

    Verify the motor encoder mounting is secure and its coupling to the motor shaft is tight. Check encoder wiring for damage or noise.

  3. 3

    Review and adjust the position loop tuning parameters (e.g., S-0-0103) and position window monitoring (S-0-0044) in the DIAX04 SSE-03VRS controller.

  4. 4

    Ensure the motor is properly sized for the application load and is not operating in a stalled or overloaded condition.

  5. 5

    If the problem persists, monitor the encoder feedback signals and compare them against the commanded trajectory using diagnostic tools. Consider replacing the encoder.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026