Indramat · DIAX 04
The DIAX04 SSE-03VRS power supply unit's internal heatsink temperature has exceeded its maximum safe operating limit, resulting in a shutdown. This protects the power components from thermal damage. It typically signifies insufficient cooling or sustained overloading of the power supply unit.
Click steps to track your progress.
Allow the DIAX04 SSE-03VRS power supply unit to cool down completely before attempting a reset.
Inspect the cooling fan on the power supply unit for proper operation, obstructions, and cleanliness.
Clean any dust or debris from the heat sink fins of the DIAX04 SSE-03VRS power supply unit.
Verify the ambient temperature in the control cabinet is within the specified operating range.
Check the load on the power supply unit and ensure it is not continuously exceeding its rated capacity. Reduce load or consider a larger power supply.