Indramat · DIAX 04
The DIAX04 SSE-03VRS power supply unit has detected an error with one or more of its internal control voltage supplies: +24V, +/-15V, or +5V. These voltages are critical for the drive's control electronics, I/O, and communication circuits. A fault in any of these indicates an internal power supply issue, compromising the drive's functionality.
Click steps to track your progress.
Perform a power cycle of the DIAX04 SSE-03VRS drive. Sometimes transient loads can cause temporary voltage dips.
Check for any external loads connected to the power supply unit's auxiliary outputs that might be drawing excessive current or causing a short.
If accessible, measure the voltage levels of +24V, +/-15V, and +5V at test points on the DIAX04 SSE-03VRS power supply unit's control board.
Inspect the internal components of the power supply unit for signs of overheating, bulging capacitors, or other visible damage.
If measurements confirm a voltage issue and no external cause is found, this indicates an internal hardware fault within the DIAX04 SSE-03VRS power supply unit, requiring factory service or replacement.