Indramat · DIAX 04
The DIAX04 SSE-03VRS drive failed to receive two consecutive Master Data Telegrams (MDT) from the master controller. The MDT carries critical command and data information. This is a communication breakdown, indicating that the drive is not receiving necessary instructions, leading to an immediate shutdown to prevent uncontrolled operation.
Click steps to track your progress.
Inspect the communication cable (e.g., fiber optic, Ethernet) connecting the DIAX04 SSE-03VRS drive to the master controller. Check for physical damage, proper termination, and secure connections.
Verify the status of the master controller and ensure it is actively transmitting MDTs. Check its diagnostic logs.
Check communication ring integrity (if applicable) for breaks or faulty nodes. Bypass or isolate sections to identify the problematic segment.
Review and verify communication parameters (e.g., S-0-0012, S-0-0013) in the DIAX04 SSE-03VRS drive and the master controller for consistency.
Monitor communication diagnostic indicators on both the master and the DIAX04 SSE-03VRS. If the fault persists, consider a faulty communication interface on the drive.