The DIAX04 SSE-03VRS drive's integrated safety function 'Safe Halt' (SH) is active and being monitored. This fault indicates that the SH condition is not being met or is being violated. Safe Halt ensures the motor is brought to a standstill and maintained there, preventing unintended startup. A violation typically signifies motion when none is expected or a failure to achieve a safe halt.
Click steps to track your progress.
Verify that the motor and machine axis are completely stopped and free from external forces when Safe Halt is active.
Inspect the motor encoder and its wiring for proper function and accurate speed/position feedback to the DIAX04 SSE-03VRS drive.
Check the configuration of Safe Halt parameters (e.g., S-0-0005, S-0-0006) and associated safety input signals in the DIAX04 SSE-03VRS for correctness.
Monitor the actual motor speed/position feedback via diagnostics to determine if unintended motion is present.
If the fault persists and no external motion or feedback issue is identified, consider a fault with the DIAX04 SSE-03VRS drive's internal safety module.