Indramat · DIAX 04
The DIAX04 SSE-03VRS drive detected an error during the activation or deactivation of an integrated safety function. This means the safety state transition did not occur as expected, potentially due to incorrect input signals, parameter mismatch, or an internal fault. The drive faults to prevent an unsafe or undefined state.
Click steps to track your progress.
Verify the status of all safety input signals connected to the DIAX04 SSE-03VRS drive. Ensure they are correct for the intended safety function activation.
Check the configuration of all active safety functions and their associated parameters in the DIAX04 SSE-03VRS drive for consistency and correctness.
Inspect all wiring for safety-related inputs for damage, loose connections, or incorrect termination.
If using an external safety PLC or relay, verify its output signals to the DIAX04 SSE-03VRS are correct and synchronized.
Perform a full power cycle of the DIAX04 SSE-03VRS system. If the fault persists, consider a fault with the drive's internal safety module.