Indramat · DIAX 04
The DIAX04 SSE-03VRS drive's safety module performed a data crosscheck (e.g., between redundant channels or expected values) and found a discrepancy. This is a critical safety fault indicating an internal inconsistency in safety-related data processing, which means the safety system cannot reliably determine the safe state. The drive faults to prevent unsafe operation.
Click steps to track your progress.
Perform a full power cycle of the DIAX04 SSE-03VRS drive. Sometimes transient conditions can cause this fault.
Check the environmental conditions (e.g., temperature, humidity) around the DIAX04 SSE-03VRS drive. Ensure stable control power.
Attempt to re-flash or update the firmware of the DIAX04 SSE-03VRS drive, especially the safety-related firmware, to rule out corruption.
Reload known good safety parameters or revert to default safety configuration and re-configure.
If the fault persists after these steps, it strongly indicates an internal hardware fault within the DIAX04 SSE-03VRS drive's safety module, requiring factory service or replacement.