F634

Emergency-Stop

Indramat · DIAX 04

What does F634 mean?

The DIAX04 SSE-03VRS drive has received an Emergency-Stop command, leading to an immediate and safe shutdown of the controlled axis. This fault is triggered by the activation of a safety-rated E-Stop circuit, which is critical for preventing injury or damage in hazardous situations. This typically implies an external E-Stop input.

Common Causes

  • An external Emergency-Stop button was pressed or activated by an operator.
  • A safety light curtain, safety gate, or other safety device connected to the DIAX04 SSE-03VRS safety input was triggered.
  • Fault in the external safety circuit (e.g., wiring short, sensor failure) that falsely activated the E-Stop input.
  • Incorrect wiring or configuration of the E-Stop input to the DIAX04 SSE-03VRS drive.
  • Internal fault within the DIAX04 SSE-03VRS drive's safety input monitoring system.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Identify and reset all activated Emergency-Stop buttons and external safety devices in the system.

  2. 2

    Inspect the entire E-Stop safety circuit, including wiring, buttons, and safety relays, for damage, loose connections, or incorrect operation.

  3. 3

    Verify the status of the E-Stop input on the DIAX04 SSE-03VRS drive through its diagnostics to ensure the signal is clear.

  4. 4

    Ensure the E-Stop wiring connected to the DIAX04 SSE-03VRS is correctly terminated and free from shorts or open circuits.

  5. 5

    If the E-Stop was not intentionally activated, systematically test each component of the external safety chain to isolate the faulty component or wiring section.

Browse all codes in this manual (60)
Verified technical data. Last updated: April 2026