E2049

Positioning velocity >= limit value

Indramat · IndraDrive MPx02

What does E2049 mean?

The actual positioning velocity of the motor in the IndraDrive MPx02 has reached or exceeded the configured velocity limit. This is a warning indicating that the motor is operating at its maximum allowed speed, potentially due to an aggressive command, incorrect scaling, or an unexpected external condition.

Common Causes

  • Commanded velocity from the master controller is too high, exceeding the configured limit.
  • Incorrect velocity scaling parameters in the drive or master controller.
  • Mechanical system feedback issue causing an overspeed indication from the encoder.
  • A motion profile is requesting velocity beyond the design limits of the motor or machine.
  • Unexpected external forces aiding motion, leading to exceeding velocity limits.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the commanded velocity from the master control system and compare it against the drive's configured velocity limits (e.g., P-0-0090, Velocity command value limit).

  2. 2

    Adjust the commanded velocity or the motion profile to ensure it stays within the mechanical and electrical limits of the system and the drive.

  3. 3

    Review any velocity scaling parameters in the IndraDrive MPx02 or the master controller to ensure correct unit conversion and limits.

  4. 4

    Monitor the actual velocity feedback to confirm its accuracy and rule out encoder issues if the motor does not appear to be moving excessively fast.

  5. 5

    If a higher velocity is required, ensure the mechanical system can safely handle it, then increase the drive's velocity limit parameters.

Browse all codes in this manual (56)
Verified technical data. Last updated: April 2026

Related Faults

E2010Position control with encoder 2 not possibleE2011PLC - Warning no. 1E2012PLC - Warning no. 2