Indramat · IndraDrive MPx02
The actual positioning velocity of the motor in the IndraDrive MPx02 has reached or exceeded the configured velocity limit. This is a warning indicating that the motor is operating at its maximum allowed speed, potentially due to an aggressive command, incorrect scaling, or an unexpected external condition.
Click steps to track your progress.
Verify the commanded velocity from the master control system and compare it against the drive's configured velocity limits (e.g., P-0-0090, Velocity command value limit).
Adjust the commanded velocity or the motion profile to ensure it stays within the mechanical and electrical limits of the system and the drive.
Review any velocity scaling parameters in the IndraDrive MPx02 or the master controller to ensure correct unit conversion and limits.
Monitor the actual velocity feedback to confirm its accuracy and rule out encoder issues if the motor does not appear to be moving excessively fast.
If a higher velocity is required, ensure the mechanical system can safely handle it, then increase the drive's velocity limit parameters.