E2059

Velocity command value limit activ

Indramat · IndraDrive MPx02

What does E2059 mean?

The current velocity command value for the IndraDrive MPx02 is being limited by a configured maximum velocity parameter. This is a warning indicating that the requested velocity exceeds the allowed limit, and the drive is automatically capping it to prevent overspeed or mechanical stress.

Common Causes

  • The commanded velocity from the master controller exceeds the maximum allowed velocity set in a drive parameter (e.g., P-0-0090, Velocity command value limit).
  • Incorrect application scaling or unit conversion for the velocity command.
  • A safety-related velocity limit is active, overriding the standard operating limits.
  • The velocity limit parameter is set too conservatively for the intended operation.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the current value of the velocity limit parameter (e.g., P-0-0090) in the IndraDrive MPx02 and compare it to the commanded velocity from the master controller.

  2. 2

    Adjust the commanded velocity from the master controller to be within the allowed range of the IndraDrive MPx02 and the application's mechanical limits.

  3. 3

    If a higher velocity is legitimately required, review and increase the velocity limit parameter in the drive configuration, ensuring it remains within the motor and mechanical system capabilities.

  4. 4

    Check for any active safety functions or system interlocks that might be imposing additional velocity limitations.

Browse all codes in this manual (56)