Indramat · IndraDrive MPx02
The IndraDrive MPx02 has detected disturbances or errors in the feedback signals from the measuring encoder. These disturbances can include signal loss, noise, intermittent faults, or incorrect signal levels, impacting position and velocity accuracy, especially in applications with direct machine feedback or closed-loop position control.
Click steps to track your progress.
Power down the drive and inspect all connections of the measuring encoder at both the encoder and the IndraDrive MPx02, ensuring they are clean, tight, and correctly wired.
Check the measuring encoder cable for damage, proper shielding, and separation from power cables to minimize electrical noise interference.
Verify the measuring encoder parameters in the IndraDrive MPx02 (e.g., type, resolution) match the installed encoder's specifications.
Inspect the measuring encoder for mechanical integrity, ensuring it is securely mounted and its coupling to the machine's axis is sound and free of play.
If the issue persists, consider temporarily swapping the encoder (if possible) or performing diagnostic checks on the encoder signals with an oscilloscope to rule out a faulty encoder.