Indramat · IndraDrive MPx02
The IndraDrive MPx02 has detected that the associated supply module is operating close to its maximum continuous load capacity, indicating a potential for overload if current conditions persist or increase. This is a prewarning to allow corrective action before an actual overload fault occurs and shuts down the system.
Click steps to track your progress.
Reduce the load on the motor or adjust the application's duty cycle to lower the power demand on the supply module.
Check the ambient temperature around the supply module and ensure proper ventilation, clearing any obstructions to airflow.
Inspect the supply module's cooling fan for proper operation and ensure its heatsink is free of dust and debris.
Verify that the supply module and motor parameters in the IndraDrive MPx02 are correctly configured for the application and match installed hardware.
If the overload prewarning is frequent, consider upgrading to a higher-rated supply module to match the application's continuous power requirements.