Indramat · IndraDrive MPx02
The IndraDrive MPx02 has detected that the acceleration commanded by the master axis generator is zero. In some motion control scenarios, especially those involving dynamic following, a zero acceleration from the master can indicate an unexpected or incorrect master motion profile, potentially leading to issues for slave axes.
Click steps to track your progress.
Review the motion profile or program being executed by the master axis generator to ensure it is correctly generating acceleration commands for the current motion phase.
Verify the parameters related to acceleration and jerk limits in both the master axis and the IndraDrive MPx02 (slave axis) to ensure coordinated operation.
Check if the master axis is operating in a mode that intentionally commands zero acceleration, and if so, confirm that this is acceptable for the application and the slave's reaction.
If the master axis is expected to accelerate, troubleshoot the master controller or motion generator for issues in its profile calculation or command generation.