Indramat · IndraDrive MPx02
The IndraDrive MPx02 has not reached the "ready for operation" state, meaning it cannot accept motion commands or enable its power section. This typically occurs because certain prerequisite conditions have not been met, or other active warnings/errors are preventing full readiness.
Click steps to track your progress.
Check the drive's display and diagnostic messages for any other active warnings or errors that might be preventing it from becoming ready. Resolve those first.
Verify that the DC bus voltage is stable and within the acceptable range for the IndraDrive MPx02.
Ensure that all safety circuits are closed and the drive enable signal is active and correctly provided by the master controller.
Review the drive's configuration parameters to ensure all necessary settings (e.g., motor data, encoder data, limits) are correctly entered and saved.
Perform a full drive reset or power cycle if no other errors are apparent, and re-attempt to enable the drive.